About 76,500 results
Open links in new tab
  1. Introduction to Modbus and Modbus Function Codes

    Jan 30, 2023 · Introduction to Modbus and Modbus Function Codes Modbus is one of the oldest industrial communication protocols still in use today. Continue reading to find out how the …

  2. How-To: Building a PLC Project with Modbus Communication

    Apr 5, 2022 · Modbus is a communication protocol stemming from the early days of Modicon PLCs, but is still common today. These two example implementations of Modbus transactions …

  3. Modbus client application | Automation & Control Engineering …

    Jan 9, 2024 · Open Modbus adds two other IEEE754 32 bit floating formats with its LE button which selects between Big Endian and Little Endian. Win-tech two standard FP formats …

  4. Modbus Time Out Error | Automation & Control Engineering Forum

    Aug 12, 2019 · Modbus slaves can not initiate a transaction - cannot send on their own. The problem could be almost anything - Devices must be Modbus enabled. Just because a device …

  5. Timeout error | Automation & Control Engineering Forum

    Feb 10, 2025 · Modbus Poll is a Modbus master simulator. If your ESP32 is indeed a master, then this won't work, as a Modbus master cannot communicate to another Modbus master.

  6. Modbus TCP cable | Automation & Control Engineering Forum

    Jan 15, 2025 · Hello, Is it possible to run Modbus TCP protocol if cable lenght is 130-140m? It will work if I use cat6 instead of cat5? do you have experience with that?

  7. what are MODBUS FC 5,6,15,16 - Control.com

    Mar 13, 2024 · I am almost new in Modbus protocol. I have some questions about Function Codes used in Modbus. We have Inputs & Outputs in Slave that should be read or written by master. …

  8. Modbus errors | Automation & Control Engineering Forum

    May 22, 2012 · Modbus Poll is the master and you must disconnect the existing master before using it. If the situation is that you actually use Modbus Poll as master the problem could be …

  9. Modbus TCP Slave Request Rejected - Control.com

    Dec 9, 2016 · I have a genset controller as slave for Modbus TCP/IP. Simply attempt to communicate from my laptop. All client software (Modbus Poll, Modscan32...

  10. Modbus Simulator Software (Master/Client) - Control.com

    Aug 25, 2025 · A while ago, I created a Modbus simulator (Master/Client) and made it available for download. If you'd like to try it out, feel free. It's available for Windows and Linux. …